![]() If gear 3 has failed, you will be able to see a pronounced groove in it. Turn on the circuit breaker and check if the timer works. Tighten the pump’s wires sitting in the motor housing. ![]() Do the same steps as steps 2 and 3 for the pool pump timer going between the timer and the pump. Im thinking if it is a stripped gear, it's either going to be gear 1 or 2, maybe 3. Loosen the wires from the back of the pool pump’s timer between the timer and the breaker, then perform the same method as step 3. 24-Hour Mechanical Time Switch, 480 VAC, 60Hz, DPST, Indoor/Outdoor Metal Enclosure, 1 Hour Interval. If you just replaced the timer motor, gear 4 is probably ok. 24-Hour Mechanical Time Switch, 208-277 VAC, 60Hz, 1 NO/1 NC, SPDT, Indoor/Outdoor Metal Enclosure, 1 Hour Interval. Gear 4 comes with the new timer motor and sticks through the mounting plate and engages gear 2. It is fitted with a back up battery to store and maintain settings for up to seven days. Click Here to Find Your New Intermatic T104 Pool Timer. Close the timer door and enjoy the energy savings with using a timer. The yellow clock dial should be spinning and the equipment should turn on and off at the set time. ![]() You can see how this disengages gear 1 from 3 to set the time. The MTeC is a digital time clock for any time based requirement. The Intermatic T104 Series Timer should now be successfully installed. If you follow the instructions in section 4, 5 and 6 of the owners manual, starting a the bottom of page 9, it will guide you thru how to wire up the motor, and how to program run times. No external time clock is needed with Hayward VS pumps. I have pulled the clock wheel out in this picture like you would to set the correct time. By 2021 most new pool pumps sold in the U.S. You can see the spring between the clock wheel, and the current time pointer(silver). When wiring this timer up, one leg of the power is always hot to the pump and the other leg goes through the timer. The spring keeps the clock wheel engaged to gear 3. Here are a few of the most common spa or pool pump timer problems and troubleshooting tips: Of course the most common problem is the timeclock will not turn on. Intermatic timeclock for two speed pumps. Were just looking at the gears on this side of the mounting plate.Ĭan you rotate the yellow clock wheel without having to pull it out? If so, this would suggest a broken or missing spring, or stripped gear 1 or 3. 1 being the largest, down to 4 the smallest. Sounds like your dial has lost its spring, or you have one or more stripped gears.įor ease, lets number the gears in these pictures.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |